BI / NI M8–M30
GWIEC
BI and NI sensors offer flush and non-flush metal-detection options in M8–M30 housings. The selection tables preserve the complete NPN and PNP catalog codes.
| Outward appearance code | M8 | M12 | |||
| Installation | Flush | Non-flush | Flush | Non-flush | |
| Detection distance | 1.5 mm ±10% | 2 mm ±10% | 2 mm ±10% | 4 mm ±10% | |
| Product photograph | View original image BI / M8 flush product photograph | View original image NI / M8 non-flush product photograph | View original image BI / M12 flush product photograph | View original image NI / M12 non-flush product photograph | |
| Output | NPN normally open | Bi1.5-EG08-AN6X/1131 | NI3-EG08-AP6X/V1131 | Bi4-M12-AN6X/H1141 | Ni4-M12-AN6X/H1141 |
| NPN normally closed | Bi2-EG08-RN6X/1131 | — | Bi4-M12-RN6X/H1141 | Ni4-M12-RN6X/H1141 | |
| NPN normally open + closed | — | — | — | — | |
| Output | PNP normally open | Bi1.5-EG08-AP6X/1131 | NI3-EG08-AP6X/V1131 | Bi2-G12-AP6X/H1141 | Ni5-G12-AP6X/H1141 |
| PNP normally closed | Bi2-EG08-RP6X/1131 | — | BI2-G12-RP6X/H1141 | Ni5-G12-RP6X/H1141 | |
| PNP normally open + closed | — | — | — | — | |
| Output | DC two-wire normally open | — | — | — | — |
| DC two-wire normally closed | — | — | — | — | |
| Output | AC two-wire normally open | — | — | — | — |
| AC two-wire normally closed | — | — | — | — | |
| AC two-wire normally open + closed | — | — | — | — | |
| Technical parameters | |||||
| Set distance | 0–1.2 mm | 0–1.6 mm | 0–1.6 mm | 0–3.2 mm | |
| Standard target | Steel 8 x 8 x 1 mm | Steel 12 x 12 x 1 mm | Steel 12 x 12 x 1 mm | Steel 15 x 15 x 1 mm | |
| Supply voltage | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | |
| Switching point tolerance | ±10% | ±10% | ±10% | ±10% | |
| Load / output requirement | <150 mA | <200 mA | <200 mA | <200 mA | |
| Voltage drop | <2.5 V | <2.5 V | <2.5 V | <2.5 V | |
| Consumption current | <10 mA | <10 mA | <10 mA | <10 mA | |
| Hysteresis | 1–20% | 1–20% | 1–20% | 1–20% | |
| Repeatability | <3% | <3% | <3% | <3% | |
| Switching frequency | 1500 Hz DC; 25 Hz AC for AC variants | 800 Hz DC; 25 Hz AC for AC variants | 600 Hz DC; 25 Hz AC for AC variants | 400 Hz DC; 25 Hz AC for AC variants | |
| Indicator | Red LED | Red LED | Red LED | Red LED | |
| Reverse polarity protection | Yes | Yes | Yes | Yes | |
| Surge protection | Yes | Yes | Yes | Yes | |
| Short circuit protection | Yes | Yes | Yes | Yes | |
| Ambient temperature | −25 to +70 °C | −25 to +70 °C | −25 to +70 °C | −25 to +70 °C | |
| Ambient humidity | 35–95% RH | 35–95% RH | 35–95% RH | 35–95% RH | |
| Protection rating | IP67 | IP67 | IP67 | IP67 | |
| Housing material | Nickel-plated brass | Nickel-plated brass | Nickel-plated brass | Nickel-plated brass | |
| Connection | 2 m PUR cable; M12 connector option shown | 2 m PUR cable; M12 connector option shown | 2 m PUR cable; M12 connector option shown | 2 m PUR cable; M12 connector option shown | |
| Catalog marking | CE symbol shown in catalog | CE symbol shown in catalog | CE symbol shown in catalog | CE symbol shown in catalog | |
| Engineering drawing Click to enlarge | View original image BI / NI M8 / M12 engineering drawing | View original image BI / NI M8 / M12 engineering drawing | |||
| Outward appearance code | M18 | M30 | |||
| Installation | Flush | Non-flush | Flush | Non-flush | |
| Detection distance | 5 mm ±10% | 8 mm ±10% | 10 mm ±10% | 15 mm ±10% | |
| Product photograph | View original image BI / M18 flush product photograph | View original image NI / M18 non-flush product photograph | View original image BI / M30 flush product photograph | View original image NI / M30 non-flush product photograph | |
| Output | NPN normally open | Bi5-M18-AN6X/H1141 | Ni8-M18-AN6X/H1141 | Bi10-M30-AN6X/H1141 | Ni15-M30-AN6X/H1141 |
| NPN normally closed | Bi5-M18-RN6X/H1141 | Ni8-M18-RN6X/H1141 | Bi10-M30-RN6X/H1141 | Ni15-M30-RN6X/H1141 | |
| NPN normally open + closed | — | — | — | — | |
| Output | PNP normally open | Bi5-G18-AP6X/H1141 | Ni10-G18-AP6X/H1141 | Bi10-G30-AP6X/H1141 | Ni15-G30-AP6X/H1141 |
| PNP normally closed | Bi5-G18-RP6X/H1141 | Ni10-G18-RP6X/H1141 | Bi10-G30-RP6X/H1141 | Ni15-G30-RP6X/H1141 | |
| PNP normally open + closed | — | — | — | — | |
| Output | DC two-wire normally open | — | — | — | — |
| DC two-wire normally closed | — | — | — | — | |
| Output | AC two-wire normally open | — | — | — | — |
| AC two-wire normally closed | — | — | — | — | |
| AC two-wire normally open + closed | — | — | — | — | |
| Technical parameters | |||||
| Set distance | 0–4 mm | 0–7 mm | 0–8 mm | 0–13 mm | |
| Standard target | Steel 18 x 18 x 1 mm | Steel 30 x 30 x 1 mm | Steel 30 x 30 x 1 mm | Steel 54 x 54 x 1 mm | |
| Supply voltage | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | |
| Switching point tolerance | ±10% | ±10% | ±10% | ±10% | |
| Load / output requirement | <200 mA | <200 mA | <200 mA | <200 mA | |
| Voltage drop | <2.5 V | <2.5 V | <2.5 V | <2.5 V | |
| Consumption current | <10 mA | <10 mA | <10 mA | <10 mA | |
| Hysteresis | 1–20% | 1–20% | 1–20% | 1–20% | |
| Repeatability | <3% | <3% | <3% | <3% | |
| Switching frequency | 600 Hz DC; 25 Hz AC for AC variants | 400 Hz DC; 25 Hz AC for AC variants | 400 Hz DC; 25 Hz AC for AC variants | 400 Hz DC; 25 Hz AC for AC variants | |
| Indicator | Red LED | Red LED | Red LED | Red LED | |
| Reverse polarity protection | Yes | Yes | Yes | Yes | |
| Surge protection | Yes | Yes | Yes | Yes | |
| Short circuit protection | Yes | Yes | Yes | Yes | |
| Ambient temperature | −25 to +70 °C | −25 to +70 °C | −25 to +70 °C | −25 to +70 °C | |
| Ambient humidity | 35–95% RH | 35–95% RH | 35–95% RH | 35–95% RH | |
| Protection rating | IP67 | IP67 | IP67 | IP67 | |
| Housing material | Nickel-plated brass | Nickel-plated brass | Nickel-plated brass | Nickel-plated brass | |
| Connection | 2 m PUR cable; M12 connector option shown | 2 m PUR cable; M12 connector option shown | 2 m PUR cable; M12 connector option shown | 2 m PUR cable; M12 connector option shown | |
| Catalog marking | CE symbol shown in catalog | CE symbol shown in catalog | CE symbol shown in catalog | CE symbol shown in catalog | |
| Engineering drawing Click to enlarge | View original image BI / NI M18 / M30 engineering drawing | View original image BI / NI M18 / M30 engineering drawing | |||
Selection note: The M8 non-flush header says 2 mm while its model prefix is NI3. The BI M12 NPN rows use Bi4-M12 codes, while the distance header is 2 mm and PNP rows use Bi2-G12. Confirm these exact variants before ordering.
Values are transcribed from the GWIEC sensor catalog, pages 14. A dash means no model is listed in that source cell. Nominal distance and an operating/set distance are different quantities. Select the complete model, output, supply, connection and mounting dimensions together.
Click any product photograph or engineering drawing to open the original image at full size.
Compare inductive sensor families · All proximity sensor categories · Contact GWIEC for model confirmation