E2E M8 / M12 / M18 / M30
GWIEC
Compare E2E M8, M12, M18 and M30 sensors by mounting, rated distance and output. Non-flush ratings differ from the PR family, so match the complete series and model.
| Outward appearance code | M8 | M12 | |||
| Installation | Flush | Non-flush | Flush | Non-flush | |
| Detection distance | 1.5 mm ±10% | 2 mm ±10% | 2 mm ±10% | 5 mm ±10% | |
| Product photograph | View original image E2E / M8 flush product photograph | View original image E2E / M8 non-flush product photograph | View original image E2E / M12 flush product photograph | View original image E2E / M12 non-flush product photograph | |
| Output | NPN normally open | E2E-X1R5E1 | E2E-X2ME1-Z | E2E-X2E1-Z | E2E-X5ME1-Z |
| NPN normally closed | E2E-X1R5E2 | E2E-X2ME2-Z | E2E-X2E2-Z | E2E-X5ME2-Z | |
| NPN normally open + closed | — | — | — | — | |
| Output | PNP normally open | E2E-X1R5F1 | E2E-X2MF1-Z | E2E-X2F1-Z | E2E-X5MF1-Z |
| PNP normally closed | E2E-X1R5F2 | E2E-X2MF2-Z | E2E-X2F2-Z | E2E-X5MF2-Z | |
| PNP normally open + closed | — | — | — | — | |
| Output | DC two-wire normally open | E2E-X2D1-N-Z | E2E-X4MD1-N-Z | E2E-X3D1-N-Z | E2E-X8MD1-N-Z |
| DC two-wire normally closed | E2E-X2D2-N-Z | E2E-X4MD2-N-Z | E2E-X3D2-N-Z | E2E-X8MD2-N-Z | |
| Output | AC two-wire normally open | E2E-X1R5Y1-Z | E2E-X2MY1-Z | E2E-X2Y1-Z | E2E-X5MY1-Z |
| AC two-wire normally closed | E2E-X1R5Y2-Z | E2E-X2MY2-Z | E2E-X2Y2-Z | E2E-X5MY2-Z | |
| AC two-wire normally open + closed | — | — | E2E-X3T1-Z | — | |
| Technical parameters | |||||
| Set distance | 0–1.2 mm | 0–1.6 mm | 0–1.6 mm | 0–4 mm | |
| Standard target | Steel 8 x 8 x 1 mm | Steel 12 x 12 x 1 mm | Steel 12 x 12 x 1 mm | Steel 15 x 15 x 1 mm | |
| Supply voltage | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | |
| Switching point tolerance | ±10% | ±10% | ±10% | ±10% | |
| Load / output requirement | <150 mA | <150 mA | <200 mA | <200 mA | |
| Voltage drop | <2.5 V | <2.5 V | <2.5 V | <2.5 V | |
| Consumption current | <10 mA | <10 mA | <10 mA | <10 mA | |
| Hysteresis | 1–20% | 1–20% | 1–20% | 1–20% | |
| Repeatability | <3% | <3% | <3% | <3% | |
| Switching frequency | 1500 Hz DC; 25 Hz AC for AC variants | 800 Hz DC; 25 Hz AC for AC variants | 800 Hz DC; 25 Hz AC for AC variants | 200 Hz DC; 25 Hz AC for AC variants | |
| Indicator | Red LED | Red LED | Red LED | Red LED | |
| Reverse polarity protection | Yes | Yes | Yes | Yes | |
| Surge protection | Yes | Yes | Yes | Yes | |
| Short circuit protection | Yes | Yes | Yes | Yes | |
| Ambient temperature | −25 to +70 °C | −25 to +70 °C | −25 to +70 °C | −25 to +70 °C | |
| Ambient humidity | 35–95% RH | 35–95% RH | 35–95% RH | 35–95% RH | |
| Protection rating | IP67 | IP67 | IP67 | IP67 | |
| Housing material | Nickel-plated brass | Nickel-plated brass | Nickel-plated brass | Nickel-plated brass | |
| Connection | 2 m PUR cable | 2 m PUR cable | 2 m PUR cable; M12 connector option shown | 2 m PUR cable; M12 connector option shown | |
| Catalog marking | CE symbol shown in catalog | CE symbol shown in catalog | CE symbol shown in catalog | CE symbol shown in catalog | |
| Engineering drawing Click to enlarge | View original image E2E M8 / M12 engineering drawing | View original image E2E M8 / M12 engineering drawing | |||
| Outward appearance code | M18 | M30 | |||
| Installation | Flush | Non-flush | Flush | Non-flush | |
| Detection distance | 5 mm ±10% | 10 mm ±10% | 10 mm ±10% | 18 mm ±10% | |
| Product photograph | View original image E2E / M18 flush product photograph | View original image E2E / M18 non-flush product photograph | View original image E2E / M30 flush product photograph | View original image E2E / M30 non-flush product photograph | |
| Output | NPN normally open | E2E-X5E1-Z | E2E-X10ME1-Z | E2E-X10E1-Z | E2E-X18ME1-Z |
| NPN normally closed | E2E-X5E2-Z | E2E-X10ME2-Z | E2E-X10E2-Z | E2E-X18ME2-Z | |
| NPN normally open + closed | — | — | — | — | |
| Output | PNP normally open | E2E-X5F1-Z | E2E-X10MF1-Z | E2E-X10F1-Z | E2E-X18MF1-Z |
| PNP normally closed | E2E-X5F2-Z | E2E-X10MF2-Z | E2E-X10F2-Z | E2E-X18MF2-Z | |
| PNP normally open + closed | — | — | — | — | |
| Output | DC two-wire normally open | E2E-X7D1-N-Z | E2E-X14MD1-N-Z | E2E-X10D1-N-Z | E2E-X20MD1-Z |
| DC two-wire normally closed | E2E-X7D2-N-Z | E2E-X14MD2-N-Z | E2E-X10D2-N-Z | E2E-X20MD2-Z | |
| Output | AC two-wire normally open | E2E-X5Y1-Z | E2E-X10MY1-N-Z | E2E-X10Y1-Z | E2E-X18MY1-Z |
| AC two-wire normally closed | E2E-X5Y2-Z | E2E-X10MY2-N-Z | E2E-X10Y2-Z | E2E-X18MY2-Z | |
| AC two-wire normally open + closed | E2E-X7T1-Z | — | E2E-X10T1-Z | — | |
| Technical parameters | |||||
| Set distance | 0–4 mm | 0–8 mm | 0–16 mm (catalog; confirm) | 0–16 mm | |
| Standard target | Steel 18 x 18 x 1 mm | Steel 30 x 30 x 1 mm | Steel 30 x 30 x 1 mm | Steel 54 x 54 x 1 mm | |
| Supply voltage | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | |
| Switching point tolerance | ±10% | ±10% | ±10% | ±10% | |
| Load / output requirement | <200 mA | <150 mA | <200 mA | <150 mA | |
| Voltage drop | <2.5 V | <2.5 V | <2.5 V | <2.5 V | |
| Consumption current | <10 mA | <10 mA | <10 mA | <10 mA | |
| Hysteresis | 1–20% | 1–20% | 1–20% | 1–20% | |
| Repeatability | <3% | <3% | <3% | <3% | |
| Switching frequency | 200 Hz DC; 25 Hz AC for AC variants | 400 Hz DC; 25 Hz AC for AC variants | 400 Hz DC; 25 Hz AC for AC variants | 400 Hz DC; 25 Hz AC for AC variants | |
| Indicator | Red LED | Red LED | Red LED | Red LED | |
| Reverse polarity protection | Yes | Yes | Yes | Yes | |
| Surge protection | Yes | Yes | Yes | Yes | |
| Short circuit protection | Yes | Yes | Yes | Yes | |
| Ambient temperature | −25 to +70 °C | −25 to +70 °C | −25 to +70 °C | −25 to +70 °C | |
| Ambient humidity | 35–95% RH | 35–95% RH | 35–95% RH | 35–95% RH | |
| Protection rating | IP67 | IP67 | IP67 | IP67 | |
| Housing material | Nickel-plated brass | Nickel-plated brass | Nickel-plated brass | Nickel-plated brass | |
| Connection | 2 m PUR cable; M12 connector option shown | 2 m PUR cable; M12 connector option shown | 2 m PUR cable; M12 connector option shown | 2 m PUR cable; M12 connector option shown | |
| Catalog marking | CE symbol shown in catalog | CE symbol shown in catalog | CE symbol shown in catalog | CE symbol shown in catalog | |
| Engineering drawing Click to enlarge | View original image E2E M18 / M30 engineering drawing | View original image E2E M18 / M30 engineering drawing | |||
Selection note: The M30 flush set-distance cell is printed 0–16 mm against a 10 mm nominal distance. Confirm the usable gap before selection. Supply and switching-frequency lines include AC data, but an AC model must be selected from the relevant output row.
Values are transcribed from the GWIEC sensor catalog, pages 12–13. A dash means no model is listed in that source cell. Nominal distance and an operating/set distance are different quantities. Select the complete model, output, supply, connection and mounting dimensions together.
Click any product photograph or engineering drawing to open the original image at full size.
Compare inductive sensor families · All proximity sensor categories · Contact GWIEC for model confirmation