Products
Home » Products » Proximity Sensor » Inductive Sensor » E2E Series Cylindrical Inductive Proximity Sensors

loading

E2E Series Cylindrical Inductive Proximity Sensors

Compare E2E M8, M12, M18 and M30 sensors by mounting, rated distance and output. Non-flush ratings differ from the PR family, so match the complete series and model.
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
sharethis sharing button
  • E2E M8 / M12 / M18 / M30

  • GWIEC

GWIEC SENSOR SERIES

E2E Series Cylindrical Inductive Proximity Sensors

Compare E2E M8, M12, M18 and M30 sensors by mounting, rated distance and output. Non-flush ratings differ from the PR family, so match the complete series and model.

E2E M8 / M12

Outward appearance code M8 M12
Installation Flush Non-flush Flush Non-flush
Detection distance 1.5 mm ±10% 2 mm ±10% 2 mm ±10% 5 mm ±10%
Product photograph View original image View original image View original image View original image
Output NPN normally open E2E-X1R5E1 E2E-X2ME1-Z E2E-X2E1-Z E2E-X5ME1-Z
NPN normally closed E2E-X1R5E2 E2E-X2ME2-Z E2E-X2E2-Z E2E-X5ME2-Z
NPN normally open + closed — — — —
Output PNP normally open E2E-X1R5F1 E2E-X2MF1-Z E2E-X2F1-Z E2E-X5MF1-Z
PNP normally closed E2E-X1R5F2 E2E-X2MF2-Z E2E-X2F2-Z E2E-X5MF2-Z
PNP normally open + closed — — — —
Output DC two-wire normally open E2E-X2D1-N-Z E2E-X4MD1-N-Z E2E-X3D1-N-Z E2E-X8MD1-N-Z
DC two-wire normally closed E2E-X2D2-N-Z E2E-X4MD2-N-Z E2E-X3D2-N-Z E2E-X8MD2-N-Z
Output AC two-wire normally open E2E-X1R5Y1-Z E2E-X2MY1-Z E2E-X2Y1-Z E2E-X5MY1-Z
AC two-wire normally closed E2E-X1R5Y2-Z E2E-X2MY2-Z E2E-X2Y2-Z E2E-X5MY2-Z
AC two-wire normally open + closed — — E2E-X3T1-Z —
Technical parameters
Set distance 0–1.2 mm 0–1.6 mm 0–1.6 mm 0–4 mm
Standard target Steel 8 x 8 x 1 mm Steel 12 x 12 x 1 mm Steel 12 x 12 x 1 mm Steel 15 x 15 x 1 mm
Supply voltage 6–36 V DC; 90–250 V AC for AC variants 6–36 V DC; 90–250 V AC for AC variants 6–36 V DC; 90–250 V AC for AC variants 6–36 V DC; 90–250 V AC for AC variants
Switching point tolerance ±10% ±10% ±10% ±10%
Load / output requirement <150 mA <150 mA <200 mA <200 mA
Voltage drop <2.5 V <2.5 V <2.5 V <2.5 V
Consumption current <10 mA <10 mA <10 mA <10 mA
Hysteresis 1–20% 1–20% 1–20% 1–20%
Repeatability <3% <3% <3% <3%
Switching frequency 1500 Hz DC; 25 Hz AC for AC variants 800 Hz DC; 25 Hz AC for AC variants 800 Hz DC; 25 Hz AC for AC variants 200 Hz DC; 25 Hz AC for AC variants
Indicator Red LED Red LED Red LED Red LED
Reverse polarity protection Yes Yes Yes Yes
Surge protection Yes Yes Yes Yes
Short circuit protection Yes Yes Yes Yes
Ambient temperature −25 to +70 °C −25 to +70 °C −25 to +70 °C −25 to +70 °C
Ambient humidity 35–95% RH 35–95% RH 35–95% RH 35–95% RH
Protection rating IP67 IP67 IP67 IP67
Housing material Nickel-plated brass Nickel-plated brass Nickel-plated brass Nickel-plated brass
Connection 2 m PUR cable 2 m PUR cable 2 m PUR cable; M12 connector option shown 2 m PUR cable; M12 connector option shown
Catalog marking CE symbol shown in catalog CE symbol shown in catalog CE symbol shown in catalog CE symbol shown in catalog
Engineering drawing
Click to enlarge
View original image View original image

E2E M18 / M30

Outward appearance code M18 M30
Installation Flush Non-flush Flush Non-flush
Detection distance 5 mm ±10% 10 mm ±10% 10 mm ±10% 18 mm ±10%
Product photograph View original image View original image View original image View original image
Output NPN normally open E2E-X5E1-Z E2E-X10ME1-Z E2E-X10E1-Z E2E-X18ME1-Z
NPN normally closed E2E-X5E2-Z E2E-X10ME2-Z E2E-X10E2-Z E2E-X18ME2-Z
NPN normally open + closed — — — —
Output PNP normally open E2E-X5F1-Z E2E-X10MF1-Z E2E-X10F1-Z E2E-X18MF1-Z
PNP normally closed E2E-X5F2-Z E2E-X10MF2-Z E2E-X10F2-Z E2E-X18MF2-Z
PNP normally open + closed — — — —
Output DC two-wire normally open E2E-X7D1-N-Z E2E-X14MD1-N-Z E2E-X10D1-N-Z E2E-X20MD1-Z
DC two-wire normally closed E2E-X7D2-N-Z E2E-X14MD2-N-Z E2E-X10D2-N-Z E2E-X20MD2-Z
Output AC two-wire normally open E2E-X5Y1-Z E2E-X10MY1-N-Z E2E-X10Y1-Z E2E-X18MY1-Z
AC two-wire normally closed E2E-X5Y2-Z E2E-X10MY2-N-Z E2E-X10Y2-Z E2E-X18MY2-Z
AC two-wire normally open + closed E2E-X7T1-Z — E2E-X10T1-Z —
Technical parameters
Set distance 0–4 mm 0–8 mm 0–16 mm (catalog; confirm) 0–16 mm
Standard target Steel 18 x 18 x 1 mm Steel 30 x 30 x 1 mm Steel 30 x 30 x 1 mm Steel 54 x 54 x 1 mm
Supply voltage 6–36 V DC; 90–250 V AC for AC variants 6–36 V DC; 90–250 V AC for AC variants 6–36 V DC; 90–250 V AC for AC variants 6–36 V DC; 90–250 V AC for AC variants
Switching point tolerance ±10% ±10% ±10% ±10%
Load / output requirement <200 mA <150 mA <200 mA <150 mA
Voltage drop <2.5 V <2.5 V <2.5 V <2.5 V
Consumption current <10 mA <10 mA <10 mA <10 mA
Hysteresis 1–20% 1–20% 1–20% 1–20%
Repeatability <3% <3% <3% <3%
Switching frequency 200 Hz DC; 25 Hz AC for AC variants 400 Hz DC; 25 Hz AC for AC variants 400 Hz DC; 25 Hz AC for AC variants 400 Hz DC; 25 Hz AC for AC variants
Indicator Red LED Red LED Red LED Red LED
Reverse polarity protection Yes Yes Yes Yes
Surge protection Yes Yes Yes Yes
Short circuit protection Yes Yes Yes Yes
Ambient temperature −25 to +70 °C −25 to +70 °C −25 to +70 °C −25 to +70 °C
Ambient humidity 35–95% RH 35–95% RH 35–95% RH 35–95% RH
Protection rating IP67 IP67 IP67 IP67
Housing material Nickel-plated brass Nickel-plated brass Nickel-plated brass Nickel-plated brass
Connection 2 m PUR cable; M12 connector option shown 2 m PUR cable; M12 connector option shown 2 m PUR cable; M12 connector option shown 2 m PUR cable; M12 connector option shown
Catalog marking CE symbol shown in catalog CE symbol shown in catalog CE symbol shown in catalog CE symbol shown in catalog
Engineering drawing
Click to enlarge
View original image View original image

Selection note: The M30 flush set-distance cell is printed 0–16 mm against a 10 mm nominal distance. Confirm the usable gap before selection. Supply and switching-frequency lines include AC data, but an AC model must be selected from the relevant output row.

Ordering and replacement selection

Values are transcribed from the GWIEC sensor catalog, pages 12–13. A dash means no model is listed in that source cell. Nominal distance and an operating/set distance are different quantities. Select the complete model, output, supply, connection and mounting dimensions together.

Click any product photograph or engineering drawing to open the original image at full size.

Compare inductive sensor families · All proximity sensor categories · Contact GWIEC for model confirmation

Previous: 
Next: 

Related Products

The ATSD1 Automatic Transfer Switch (ATSE) is a high-reliability device designed to seamlessly switch between primary and backup power sources, ensuring uninterrupted power supply in critical applications.
0
0
The LXW26 Series Universal Rotary Switch is a versatile control device designed for precise switching in industrial and commercial applications.
0
0
The GIEL7 Series Miniature Circuit Breaker (MCB) is a safety device designed to protect electrical circuits from overloads and short circuits in residential and light commercial applications.
0
0
The LR2 D Series Thermal Relay D13 is a reliable overload protection device designed for electric motors.
0
0
The 3TF Series AC Contactor 3TF47 is engineered for precision and resilience in industrial power management.
0
0
The LC1 D Series AC Contactor is a robust electrical device designed for switching and controlling AC motor circuits in industrial applications.