PR08 / PR12 / PR18 / PR30
GWIEC
PR08, PR12, PR18 and PR30 provide metal detection in M8–M30 housings. Each housing table compares flush and non-flush models, switching outputs and mechanical drawings.
| Outward appearance code | M8 (PR08) | M12 (pr012) | |||
| Installation | Flush | Non-flush | Flush | Non-flush | |
| Detection distance | 1.5 mm ±10% | 2 mm ±10% | 2 mm ±10% | 4 mm ±10% | |
| Product photograph | View original image PR08 / M8 flush product photograph | View original image PR08 / M8 non-flush product photograph | View original image PR12 / M12 flush product photograph | View original image PR12 / M12 non-flush product photograph | |
| Output | NPN normally open | PR08-1.5DN | PR08-2DN | PR12-2DN | PR12-4DN |
| NPN normally closed | PR08-1.5DN2 | PR08-2DN2 | PR12-2DN2 | PR12-4DN2 | |
| NPN normally open + closed | — | — | — | — | |
| Output | PNP normally open | PR08-1.5PN | PR08-2DP | PR12-2DP | PRT12-4DP |
| PNP normally closed | PR08-1.5PN2 | PR08-2DP2 | PR12-2DP2 | PRT12-4DP2 | |
| PNP normally open + closed | — | — | — | — | |
| Output | DC two-wire normally open | PRT08-1.5DO | PRT08-2DO | PRT12-2DO | PRT12-4DO |
| DC two-wire normally closed | PRT08-1.5DC | PRT08-2DC | PRT12-2DC | PRT12-4DC | |
| Output | AC two-wire normally open | — | — | PR12-2AO | PR12-4AO |
| AC two-wire normally closed | — | — | PR12-2AC | PR12-4AC | |
| AC two-wire normally open + closed | — | — | — | — | |
| Technical parameters | |||||
| Set distance | 0–1.2 mm | 0–1.6 mm | 0–1.6 mm | 0–3.2 mm | |
| Standard target | Steel 8 x 8 x 1 mm | Steel 12 x 12 x 1 mm | Steel 12 x 12 x 1 mm | Steel 15 x 15 x 1 mm | |
| Supply voltage | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | |
| Switching point tolerance | ±10% | ±10% | ±10% | ±10% | |
| Load / output requirement | <150 mA | <150 mA | <200 mA | <200 mA | |
| Voltage drop | <2.5 V | <2.5 V | <2.5 V | <2.5 V | |
| Consumption current | <10 mA | <10 mA | <10 mA | <10 mA | |
| Hysteresis | 1–20% | 1–20% | 1–20% | 1–20% | |
| Repeatability | <3% | <3% | <3% | <3% | |
| Switching frequency | 1500 Hz DC; 25 Hz AC for AC variants | 800 Hz DC; 25 Hz AC for AC variants | 600 Hz DC; 25 Hz AC for AC variants | 400 Hz DC; 25 Hz AC for AC variants | |
| Indicator | Red LED | Red LED | Red LED | Red LED | |
| Reverse polarity protection | Yes | Yes | Yes | Yes | |
| Surge protection | Yes | Yes | Yes | Yes | |
| Short circuit protection | Yes | Yes | Yes | Yes | |
| Ambient temperature | −25 to +70 °C | −25 to +70 °C | −25 to +70 °C | −25 to +70 °C | |
| Ambient humidity | 35–95% RH | 35–95% RH | 35–95% RH | 35–95% RH | |
| Protection rating | IP67 | IP67 | IP67 | IP67 | |
| Housing material | Nickel-plated brass | Nickel-plated brass | Nickel-plated brass | Nickel-plated brass | |
| Connection | 2 m PUR cable; M12 connector option shown | 2 m PUR cable; M12 connector option shown | 2 m PUR cable | 2 m PUR cable | |
| Catalog marking | CE symbol shown in catalog | CE symbol shown in catalog | CE symbol shown in catalog | CE symbol shown in catalog | |
| Engineering drawing Click to enlarge | View original image PR08 / PR12 engineering drawing | View original image PR08 / PR12 engineering drawing | |||
| Outward appearance code | M18 (pr018) | M30 (pr030) | |||
| Installation | Flush | Non-flush | Flush | Non-flush | |
| Detection distance | 5 mm ±10% | 8 mm ±10% | 10 mm ±10% | 15 mm ±10% | |
| Product photograph | View original image PR18 / M18 flush product photograph | View original image PR18 / M18 non-flush product photograph | View original image PR30 / M30 flush product photograph | View original image PR30 / M30 non-flush product photograph | |
| Output | NPN normally open | PR18-5DN | PR18-8DN | PR30-10DN | PR30-15DN |
| NPN normally closed | PR18-5DN2 | PR18-8DN2 | PR30-10DN2 | PR30-15DN2 | |
| NPN normally open + closed | — | — | — | — | |
| Output | PNP normally open | PR18-5DP | PR18-8DP | PR30-10DP | PR30-15DP |
| PNP normally closed | PR18-5DP2 | PR18-8DP2 | PR30-10DP2 | PR30-15DP2 | |
| PNP normally open + closed | — | — | — | — | |
| Output | DC two-wire normally open | PRT18-5DO | PRT18-8DO | PRT30-10DO | PRT30-15DO |
| DC two-wire normally closed | PRT18-5DC | PRT18-8DC | PRT30-10DC | PRT30-15DC | |
| Output | AC two-wire normally open | PR18-5AO | PR18-8AO | PR30-10AO | PR30-15AO |
| AC two-wire normally closed | PR18-5AC | PR18-8AC | PR30-10AC | PR30-15AC | |
| AC two-wire normally open + closed | — | — | — | — | |
| Technical parameters | |||||
| Set distance | 0–4 mm | 0–7 mm | 0–8 mm | 0–13 mm | |
| Standard target | Steel 18 x 18 x 1 mm | Steel 30 x 30 x 1 mm | Steel 30 x 30 x 1 mm | Steel 54 x 54 x 1 mm | |
| Supply voltage | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | |
| Switching point tolerance | ±10% | ±10% | ±10% | ±10% | |
| Load / output requirement | <200 mA | <200 mA | <200 mA | <200 mA | |
| Voltage drop | <2.5 V | <2.5 V | <2.5 V | <2.5 V | |
| Consumption current | <10 mA | <10 mA | <10 mA | <10 mA | |
| Hysteresis | 1–20% | 1–20% | 1–20% | 1–20% | |
| Repeatability | <3% | <3% | <3% | <3% | |
| Switching frequency | 600 Hz DC; 25 Hz AC for AC variants | 400 Hz DC; 25 Hz AC for AC variants | 400 Hz DC; 25 Hz AC for AC variants | 400 Hz DC; 25 Hz AC for AC variants | |
| Indicator | Red LED | Red LED | Red LED | Red LED | |
| Reverse polarity protection | Yes | Yes | Yes | Yes | |
| Surge protection | Yes | Yes | Yes | Yes | |
| Short circuit protection | Yes | Yes | Yes | Yes | |
| Ambient temperature | −25 to +70 °C | −25 to +70 °C | −25 to +70 °C | −25 to +70 °C | |
| Ambient humidity | 35–95% RH | 35–95% RH | 35–95% RH | 35–95% RH | |
| Protection rating | IP67 | IP67 | IP67 | IP67 | |
| Housing material | Nickel-plated brass | Nickel-plated brass | Nickel-plated brass | Nickel-plated brass | |
| Connection | 2 m PUR cable | 2 m PUR cable | 2 m PUR cable | 2 m PUR cable | |
| Catalog marking | CE symbol shown in catalog | CE symbol shown in catalog | CE symbol shown in catalog | CE symbol shown in catalog | |
| Engineering drawing Click to enlarge | View original image PR18 / PR30 engineering drawing | View original image PR18 / PR30 engineering drawing | |||
Selection note: The catalog uses PR, PRT and PRT12 prefixes in different output rows. Codes are retained as printed; confirm the complete suffix and supply rather than assuming that equal housing sizes are interchangeable.
Values are transcribed from the GWIEC sensor catalog, pages 11–12. A dash means no model is listed in that source cell. Nominal distance and an operating/set distance are different quantities. Select the complete model, output, supply, connection and mounting dimensions together.
Click any product photograph or engineering drawing to open the original image at full size.