| Availability: | |
|---|---|
| Quantity: | |
TL-W5 / TL-W7 / HY / HD / HE
GWIEC
Thin TL-W plate forms and larger HY, HD and HE blocks provide different sensing-face and mounting arrangements. Compare both housing dimensions and nominal gap.
| Outward appearance code | 30×18×10 | 50×25×10 | 45×30×12 | |
| Installation | Non-flush | Non-flush | Non-flush | |
| Detection distance | 5 mm ±10% | 5 mm ±10% | 7 mm ±10% | |
| Product photograph | View original image TL-W5MC / 30 x 18 x 10 product photograph | View original image TL-W5E / 50 x 25 x 10 product photograph | View original image TL-W7 / 45 x 30 x 12 product photograph | |
| Output | NPN normally open | TL-W5MC1 | TL-W5E1 | TL-W7E1 |
| NPN normally closed | TL-W5MC2 | TL-W5E2 | TL-W7E2 | |
| NPN normally open + closed | — | — | — | |
| Output | PNP normally open | TL-W5MB1 | TL-W5F1 | TL-W7F1 |
| PNP normally closed | TL-W5MB2 | TL-W5F2 | TL-W7F2 | |
| PNP normally open + closed | — | — | — | |
| Output | DC two-wire normally open | TL-W5MD1 | — | — |
| DC two-wire normally closed | TL-W5MD2 | — | — | |
| Output | AC two-wire normally open | — | — | — |
| AC two-wire normally closed | — | — | — | |
| AC two-wire normally open + closed | — | — | — | |
| Technical parameters | ||||
| Set distance | 0–4 mm | 0–4 mm | 0–5 mm | |
| Standard target | Steel 18 x 18 x 1 mm | Steel 18 x 18 x 1 mm | Steel 25 x 25 x 1 mm | |
| Supply voltage | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | |
| Switching point tolerance | ±10% | ±10% | ±10% | |
| Load / output requirement | <300 mA | <300 mA | <300 mA | |
| Voltage drop | <2.5 V | <2.5 V | <2.5 V | |
| Consumption current | <10 mA | <10 mA | <10 mA | |
| Hysteresis | 1–20% | 1–20% | 1–20% | |
| Repeatability | <3% | <3% | <3% | |
| Switching frequency | 200 Hz DC; 25 Hz AC for AC variants | 200 Hz DC; 25 Hz AC for AC variants | 200 Hz DC; 25 Hz AC for AC variants | |
| Indicator | Red LED | Red LED | Red LED | |
| Reverse polarity protection | Yes | Yes | Yes | |
| Surge protection | Yes | Yes | Yes | |
| Short circuit protection | Yes | Yes | Yes | |
| Ambient temperature | −25 to +70 °C | −25 to +70 °C | −25 to +70 °C | |
| Ambient humidity | 35–95% RH | 35–95% RH | 35–95% RH | |
| Protection rating | IP67 | IP67 | IP67 | |
| Housing material | ABS | ABS | ABS | |
| Connection | 2 m PUR cable | 2 m PUR cable | 2 m PUR cable | |
| Catalog marking | CE symbol shown in catalog | CE symbol shown in catalog | CE symbol shown in catalog | |
| Engineering drawing Click to enlarge | View original image TL-W plate forms engineering drawing | View original image TL-W plate forms engineering drawing | View original image TL-W plate forms engineering drawing | |
| Outward appearance code | 40×40×118 | 55×55×130 | 50×50×50 | 50×50×52 | ||
| Installation | Non-flush | Non-flush | Non-flush | Non-flush | Non-flush | |
| Detection distance | 15 mm ±10% | 20 mm ±10% | 30 mm ±10% | 20 mm ±10% | 25 mm ±10% | |
| Product photograph | View original image HY / 15 mm product photograph | View original image HY / 20 mm product photograph | View original image HY / 30 mm product photograph | View original image HD / 20 mm product photograph | View original image HE / 25 mm product photograph | |
| Output | NPN normally open | HY-3015A | HY-3020A | HY-3030A | HD-3020A | HE-3025A |
| NPN normally closed | HY-3015B | HY-3020B | HY-3030B | HD-3020B | HE-3025B | |
| NPN normally open + closed | HY-3015AB | HY-3020AB | HY-3030AB | — | — | |
| Output | PNP normally open | HY-3015C | HY-3020C | HY-3030C | HD-3020C | HE-3025C |
| PNP normally closed | HY-3015D | HY-3020D | HY-3030D | HD-3020D | HE-3025D | |
| PNP normally open + closed | HY-3015CD | HY-3020CD | HY-3020CD | — | — | |
| Output | DC two-wire normally open | HY-3015AL | HY-3020AL | HY-3020AL | HD-3020AL | HE-3025AL |
| DC two-wire normally closed | HY-3015BL | HY-3020BL | HY-3030BL | HD-3020BL | HE-3025BL | |
| Output | AC two-wire normally open | HY-2015A | HY-2020A | HY-2030A | HD-2020A | HE-2025A |
| AC two-wire normally closed | HY-2015B | HY-2020B | HY-2030B | HD-2020B | HE-2025B | |
| AC two-wire normally open + closed | HY-2015AB | HY-2020AB | HY-2030AB | HD-2020AB | HE-2025AB | |
| Technical parameters | ||||||
| Set distance | 0–13 mm | 0–17 mm | 0–27 mm | 0–17 mm | 0–22 mm | |
| Standard target | Steel 50 x 50 x 1 mm | Steel 50 x 50 x 1 mm | Steel 65 x 65 x 1 mm | Steel 50 x 50 x 1 mm | Steel 60 x 60 x 1 mm | |
| Supply voltage | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | |
| Switching point tolerance | ±10% | ±10% | ±10% | ±10% | ±10% | |
| Load / output requirement | <300 mA | <300 mA | <300 mA | <300 mA | <300 mA | |
| Voltage drop | <2.5 V | <2.5 V | <2.5 V | <2.5 V | <2.5 V | |
| Consumption current | <10 mA | <10 mA | <10 mA | <10 mA | <10 mA | |
| Hysteresis | 1–20% | 1–20% | 1–20% | 1–20% | 1–20% | |
| Repeatability | <3% | <3% | <3% | <3% | <3% | |
| Switching frequency | 200 Hz DC; 25 Hz AC for AC variants | 200 Hz DC; 25 Hz AC for AC variants | 200 Hz DC; 25 Hz AC for AC variants | 200 Hz DC; 25 Hz AC for AC variants | 200 Hz DC; 25 Hz AC for AC variants | |
| Indicator | Red LED | Red LED | Red LED | Red LED | Red LED | |
| Reverse polarity protection | Yes | Yes | Yes | Yes | Yes | |
| Surge protection | Yes | Yes | Yes | Yes | Yes | |
| Short circuit protection | Yes | Yes | Yes | Yes | Yes | |
| Ambient temperature | −25 to +70 °C | −25 to +70 °C | −25 to +70 °C | −25 to +70 °C | −25 to +70 °C | |
| Ambient humidity | 35–95% RH | 35–95% RH | 35–95% RH | 35–95% RH | 35–95% RH | |
| Protection rating | IP67 | IP67 | IP67 | IP67 | IP67 | |
| Housing material | ABS | ABS | ABS | ABS | ABS | |
| Connection | 2 m PUR cable | 2 m PUR cable | 2 m PUR cable | 2 m PUR cable | 2 m PUR cable | |
| Catalog marking | CE symbol shown in catalog | CE symbol shown in catalog | CE symbol shown in catalog | CE symbol shown in catalog | CE symbol shown in catalog | |
| Engineering drawing Click to enlarge | View original image HY / HD / HE engineering drawing | View original image HY / HD / HE engineering drawing | View original image HY / HD / HE engineering drawing | View original image HY / HD / HE engineering drawing | ||
Selection note: In the HY 30 mm column, the catalog prints HY-3020CD and HY-3020AL among HY-3030 rows. These two codes are preserved and require confirmation for the 30 mm variant.
Values are transcribed from the GWIEC sensor catalog, pages 19–20. A dash means no model is listed in that source cell. Nominal distance and an operating/set distance are different quantities. Select the complete model, output, supply, connection and mounting dimensions together.
Click any product photograph or engineering drawing to open the original image at full size.
Compare inductive sensor families · All proximity sensor categories · Contact GWIEC for model confirmation