| Availability: | |
|---|---|
| Quantity: | |
GC12 / GC18 / GC30
GWIEC
GC12, GC18 and GC30 provide switched capacitive detection in cylindrical housings. Select the flush or non-flush column, full output code and actual target material.
| Outward appearance code | GI12C | GI18C | ||
| Installation | Flush | Non-flush | Flush | |
| Detection distance | 2 mm ±10% | 5 mm ±10% | 5 mm ±10% | |
| Product photograph | View original image GC12 flush product photograph | View original image GC12 non-flush product photograph | View original image GC18 flush product photograph | |
| Output | NPN normally open | GC12-02N1 | GC12-04N1 | GC18-05N1 |
| NPN normally closed | GC12-02N2 | GC12-04N2 | GC18-05N2 | |
| NPN normally open + closed | — | — | — | |
| Output | PNP normally open | GC12-02P1 | GC12-04P1 | GC18-05P1 |
| PNP normally closed | GC12-02P2 | GC12-04P2 | GC18-05P2 | |
| PNP normally open + closed | — | — | — | |
| Output | DC two-wire normally open | GC12-02A1 | GC12-04A1 | GC18-05A1 |
| DC two-wire normally closed | GC12-02A2 | GC12-04A2 | GC18-05A2 | |
| Output | AC two-wire normally open | — | — | — |
| AC two-wire normally closed | — | — | — | |
| AC two-wire normally open + closed | — | — | — | |
| Technical parameters | ||||
| Set distance | 0–1.7 mm | 0–4 mm | 0–4 mm | |
| Standard target | SPCC steel 50 x 50 x 1 mm | SPCC steel 50 x 50 x 1 mm | SPCC steel 50 x 50 x 1 mm | |
| Supply voltage | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | |
| Switching point tolerance | ±10% | ±10% | ±10% | |
| Load / output requirement | <300 mA | <300 mA | <300 mA | |
| Voltage drop | <2.5 V | <2.5 V | <2.5 V | |
| Consumption current | <10 mA | <10 mA | <10 mA | |
| Hysteresis | 1–20% | 1–20% | 1–20% | |
| Repeatability | <3% | <3% | <3% | |
| Switching frequency | 50 Hz | 50 Hz | 50 Hz | |
| Indicator | Red LED | Red LED | Red LED | |
| Reverse polarity protection | Yes | Yes | Yes | |
| Surge protection | Yes | Yes | Yes | |
| Short circuit protection | Yes | Yes | Yes | |
| Ambient temperature | −25 to +70 °C | −25 to +70 °C | −25 to +70 °C | |
| Ambient humidity | 35–95% RH | 35–95% RH | 35–95% RH | |
| Protection rating | IP67 | IP67 | IP67 | |
| Housing material | Nickel-plated brass | Nickel-plated brass | Nickel-plated brass | |
| Connection | 2 m PUR cable; M8 connector option shown | 2 m PUR cable; M8 connector option shown | 2 m PUR cable; M8 connector option shown | |
| Catalog marking | CE symbol shown in catalog | CE symbol shown in catalog | CE symbol shown in catalog | |
| Engineering drawing Click to enlarge | View original image GC12 / GC18 — group 1 engineering drawing | View original image GC12 / GC18 — group 1 engineering drawing | ||
| Outward appearance code | GI18C | GI30C | ||
| Installation | Non-flush | Flush | Non-flush | |
| Detection distance | 8 mm ±10% | 10 mm ±10% | 15 mm ±10% | |
| Product photograph | View original image GC18 non-flush product photograph | View original image GC30 flush product photograph | View original image GC30 non-flush product photograph | |
| Output | NPN normally open | GC18-08N1 | GC30-10N1 | GC30-15N1 |
| NPN normally closed | GC18-08N2 | GC30-10N2 | GC30-15N2 | |
| NPN normally open + closed | — | — | — | |
| Output | PNP normally open | GC18-08P1 | GC30-10P1 | GC30-15P1 |
| PNP normally closed | GC18-08P2 | GC30-10P2 | GC30-15P2 | |
| PNP normally open + closed | — | — | — | |
| Output | DC two-wire normally open | GC18-08A1 | GC30-10A1 | GC30-15A1 |
| DC two-wire normally closed | GC18-08A2 | GC30-10A2 | GC30-15A2 | |
| Output | AC two-wire normally open | — | — | — |
| AC two-wire normally closed | — | — | — | |
| AC two-wire normally open + closed | — | — | — | |
| Technical parameters | ||||
| Set distance | 0–8 mm | 0–10 mm | 0–15 mm | |
| Standard target | SPCC steel 50 x 50 x 1 mm | SPCC steel 50 x 50 x 1 mm | SPCC steel 50 x 50 x 1 mm | |
| Supply voltage | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | 6–36 V DC; 90–250 V AC for AC variants | |
| Switching point tolerance | ±10% | ±10% | ±10% | |
| Load / output requirement | <300 mA | <300 mA | <300 mA | |
| Voltage drop | <2.5 V | <2.5 V | <2.5 V | |
| Consumption current | <10 mA | <10 mA | <10 mA | |
| Hysteresis | 1–20% | 1–20% | 1–20% | |
| Repeatability | <3% | <3% | <3% | |
| Switching frequency | 50 Hz | 50 Hz | 50 Hz | |
| Indicator | Red LED | Red LED | Red LED | |
| Reverse polarity protection | Yes | Yes | Yes | |
| Surge protection | Yes | Yes | Yes | |
| Short circuit protection | Yes | Yes | Yes | |
| Ambient temperature | −25 to +70 °C | −25 to +70 °C | −25 to +70 °C | |
| Ambient humidity | 35–95% RH | 35–95% RH | 35–95% RH | |
| Protection rating | IP67 | IP67 | IP67 | |
| Housing material | Nickel-plated brass | Nickel-plated brass | Nickel-plated brass | |
| Connection | 2 m PUR cable; M8 connector option shown | 2 m PUR cable; M8 connector option shown | 2 m PUR cable; M8 connector option shown | |
| Catalog marking | CE symbol shown in catalog | CE symbol shown in catalog | CE symbol shown in catalog | |
| Engineering drawing Click to enlarge | View original image GC18 / GC30 — group 2 engineering drawing | View original image GC18 / GC30 — group 2 engineering drawing | ||
Selection note: The catalog headings say GI12C/GI18C/GI30C, while the model rows say GC12/GC18/GC30. Its GC12 non-flush distance is printed 5 mm while model codes use -04. The A1/A2 rows are labeled DC two-wire; do not infer an AC supply from the letter A.
Values are transcribed from the GWIEC sensor catalog, pages 24–25. A dash means no model is listed in that source cell. Nominal distance and an operating/set distance are different quantities. Select the complete model, output, supply, connection and mounting dimensions together.
Click any product photograph or engineering drawing to open the original image at full size.
Compare capacitive sensor families · All proximity sensor categories · Contact GWIEC for model confirmation